Dehumidifier - Frost Buildup

Issue

  • Dehumidifier - Frost Buildup

Applies to

  • Dehumidifiers

Solution

Light frost is visible on the coils

  • Under certain normal operating conditions light frost can form on the coils. The evaporator operates at temperatures close to Freezing.
  • Low ambient temperatures can promote the formation of frost. The low limit is 41 F.
  • The unit has a sensor on the coil to detect frost and will shut off the compressor to warm the coil and melt the frost.
  • Make sure the unit has proper clearance around it and that the filter is clean.

Heavy frost or ice is visible on the coils

  • If system is imbalanced it can lower coil temperatures.
  • If the air flow is restricted it can prevent the from ice melting
  • If the setpoint is set at "CO" change to a different range (35 to 85).
  • Check the filter and clean if necessary.
  • Check to see if any error codes are displayed, if yes please refer to your use and care manual for more information.

IF YOU WERE UNABLE TO RESOLVE YOUR ISSUE

  • For units installed within the past 30 days, please refer back to your installer to resolve this issue.
  • For units installed after 30 days please contact us to schedule service.